KD-125B Smoke Alarm User Manual
2831-CPR-F2210
EN14604
1. Brief introduction
KD-125B Smoke Alarm is a photoelectric smoke alarm with low power consumption. Internal precise analog circuit and digital circuit make the detection work more stable and reliable. The product has a small size and uses large-capacity battery which can provide service life of 5 years.
2. Product characteristics
Photoelectric smoke detection
High sensitivity
Precise analog circuit and digital circuit
Low power consumption
Small size
Battery service life of 5 years
3. Technical parameters
KD-125 A
(Figure 1)
5. Installation
5.1 Functional diagram (Figure 2)
(Figure 2)
5.2 Installation Instructions
a. Hold the mounting plate against the selected installation position on the ceiling, and mark the center of the holes with a pencil. Drill a hole through the pencil marks and use the enclosed screws and anchors to secure the mounting plate. (See Figure 3)
b. Install the batteries according to Figure 3, making sure the polarity matches the markings. If the batteries are installed correctly, the red pin will drop automatically.
c. Insert the hook of the product into the slot of mounting plate. Then turn the alarm clockwise until it snaps into place.
(Figure 3)
Note: If you can’t rotate the alarm after insert the hook into the slot, please check if the battery is installed correctly.
5.3 Replacing battery
a. When low battery warning is made (please refer to section 6. Function), please replace the batteries immediately, as shown below.
Turn the alarm anticlockwise and Take the batteries out and install
remove it from the mounting plate. the new ones according to 5.2 b.
b. Use battery type: LR03/AAA.
c. Whenever the batteries are replaced, test the operation of the alarm by pressing the TEST button. If beeps are made which means the product works properly, install the alarm to the mounting plate as shown in Figure 3.
5.4 Recommended Locations for Smoke Alarms and Locations to Avoid
a. Recommended Locations for Smoke Alarms
Install at least one smoke alarm in every bedroom
If you install the smoke alarm in a passageway whose width is less than 3m, install it in the middle and install one unit every 12m.
At least 1.5m from fluorescent lamp or neon lamp. (In case of electronic interference).
At least 3m from the bathroom.
At least 6m from the kitchen or stove.
At least 30cm from the lamps.
Locate the smoke alarm in the middle of the room. If you can’t, install it at least 1m from the wall.
If you install the smoke alarm on sloped or peaked ceiling, the installation position shall be at least 90cm from the highest point.
b. Locations to Avoid
In the garage. Products of combustion are present when you start your automobile.
Near fresh air vents, fans, air conditioner or other drafty areas.
In an area where insects often appears.
In an area where the temperature may fall below 0℃ or rise above 40℃.
In humid areas. Bathroom. Kitchen.
6. Function
Testing
Press the TEST button and the product will enter alarm mode. It will make beeps that are louder than 86dB. The alarm indicator (red) will flash.
Standby condition
In standby condition, the smoke alarm detects every 10 seconds. The alarm indicator flashes every 344 seconds to indicate that the smoke alarm is operating properly. When it senses products of combustion, the alarm sounds. And the alarm indicator (red) flashes at the same time, until the air is clear.
Silence mode (Low sensitivity)
When it’s in alarm condition, press the TEST/HUSH button and the product will enter silence mode. The alarm indicator flashes every 9 seconds and no audible sound will be heard, unless smoke becomes denser. That will last for about 9 minutes. Pressing the TEST/HUSH button again will end the silence mode.
Low battery warning
When the battery voltage is too low, the product will make short beeps every 43 seconds to warn the user, until the battery voltage comply with the working voltage of the smoke alarm.
Alarm history
When the alarm indicator (green) flashes 3 times every 43 seconds, that means alarm has been made before. Please check if there is fire risk in detecting area. This indication will end 24 hours later.
Smoke chamber degeneration warning
The working environment and time will cause the degeneration of smoke chamber. When the product makes 3 short beeps every 43 seconds, it indicates end-of-unit-life. You should replace the smoke alarm with a new one.
content is empty!
Please Enter Your Information
Our main products include different kinds of smoke alarms, carbon monoxide alarms, gas alarms,water alarms,intelligent wireless alarm system , and other home electronics.
0574 62566055/62566056
+86 13245660006
+86 13081966918
13245660006
13081966918
Copyright © 2021 Ningbo Kingdun Electronic Industry Co.,Ltd.
Support by Leadong.com