Availability: | |
---|---|
Quantity: | |
LM-109E
KINGDUN
8531100000
Product Specifications:
Technical parame- ters | Smoke detector | ||
Voltage | DC3V(built-in CP952434) | ||
Low-voltage inspection |
2.2V | ||
current | Working current | Quiescent current | |
≤120mA | ≤2uA | ||
Alarm loud- ness | ≥85dB/3m | ||
Working temperature | -10℃~+40℃ | ||
Ambient humidity | ≤95%RH(no condensation) | ||
Status dis- play | Normal smoke detection | LED (red) flashes once about every 344 seconds, no alarm sound | |
Smoke detection or key test | LED (red) flashes and continuous alarm is given | ||
Low sensitivity detection (silent mode) | LED (red) flashes about every 10 seconds, no alarm sound, automatically cancel low sensi- tivity detection about 9 minutes later | ||
Alarm memory | LED (green) flashed 3 times about every 43 seconds, and stops 24 hours later. The first time you press test/mute button after alarm is made, the detector will hint by special alarm mode. | ||
End of useful life |
After working for 10 years, alarm sound is made, the buzzer buzzes 3 times about every 43 seconds | ||
Low-voltage inspection | LED (red) flashes once, make “di” alarm sound about every 43 seconds |
Appearance and dimension(Figure 1)
(Figure1)
Operation:
• In areas where ventilation and/or air conditioning systems are used is must be ensured that air movement does not affect the function of the smoke detector.
• Smoke detectors must be permanently fixed on the ceiling. Mounting instructions must be observed.
• Choose a mounting method that ensures a holding force of at least 20N in vertical direction.
• The smoke detector is designed for monitoring residential buildings or residential premises (not for industrial or commercial usage).
• A function test must be performed on each smoke detector after installation.
• The functionality of each installed smoke detector must be regularly checked and maintenance measures must be ensured. Perform function test 1 per week, clean every 3 months.
• Smoke detectors must be taken out of service at the latest after 10 years and replaced with a new device.
Product Specifications:
Technical parame- ters | Smoke detector | ||
Voltage | DC3V(built-in CP952434) | ||
Low-voltage inspection |
2.2V | ||
current | Working current | Quiescent current | |
≤120mA | ≤2uA | ||
Alarm loud- ness | ≥85dB/3m | ||
Working temperature | -10℃~+40℃ | ||
Ambient humidity | ≤95%RH(no condensation) | ||
Status dis- play | Normal smoke detection | LED (red) flashes once about every 344 seconds, no alarm sound | |
Smoke detection or key test | LED (red) flashes and continuous alarm is given | ||
Low sensitivity detection (silent mode) | LED (red) flashes about every 10 seconds, no alarm sound, automatically cancel low sensi- tivity detection about 9 minutes later | ||
Alarm memory | LED (green) flashed 3 times about every 43 seconds, and stops 24 hours later. The first time you press test/mute button after alarm is made, the detector will hint by special alarm mode. | ||
End of useful life |
After working for 10 years, alarm sound is made, the buzzer buzzes 3 times about every 43 seconds | ||
Low-voltage inspection | LED (red) flashes once, make “di” alarm sound about every 43 seconds |
Appearance and dimension(Figure 1)
(Figure1)
Operation:
• In areas where ventilation and/or air conditioning systems are used is must be ensured that air movement does not affect the function of the smoke detector.
• Smoke detectors must be permanently fixed on the ceiling. Mounting instructions must be observed.
• Choose a mounting method that ensures a holding force of at least 20N in vertical direction.
• The smoke detector is designed for monitoring residential buildings or residential premises (not for industrial or commercial usage).
• A function test must be performed on each smoke detector after installation.
• The functionality of each installed smoke detector must be regularly checked and maintenance measures must be ensured. Perform function test 1 per week, clean every 3 months.
• Smoke detectors must be taken out of service at the latest after 10 years and replaced with a new device.
content is empty!
Please Enter Your Information
0574 62566055/62566056
+86 13245660006
+86 13081966918
13245660006
13081966918
Copyright © 2021 Ningbo Kingdun Electronic Industry Co.,Ltd.
Support by Leadong.com