KD-135A/B/C/D/E Optical smoke alarm
15
1134
1134-CPR-101
EN 14604:2005/AC:2008
KD-135DoP001
The instruction of smoke alarm devices
Introduction
Design
KD-135A/B/C/D/E
Ⅰ. Technical parameter
Working Voltage:DC9V
Current:Quiescent Current:≤10uA
Alarming Current: ≤ 20mA
Alarming Decibel:≥85dB/3m
Low voltage Alarming:≤7.3V
Working Temperature: -10℃~+40℃
Working Humidity:≤95%RH
CAUTION!
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Test the alarm for correct operation using the test facility, whenever the battery is replaced.
Ⅲ、Test
Note:If the battery installed in wrong way, the detector will not work and maybe destroyed. If the detector operates smoothly, the Red LED will flash once in about 43S.
1、Contrarotate the installation panel in order to remove it;
2、Remove the insulated material and make sure the battery is connected in correct way;
3、Adjust the clips of the installation panel to the notches of the detector and turn the smoke detector clockwise in order to fasten it;
4、Depress the test button,the RED LED flashes quickly and in the mean while the detector sounds, it means the the detector works well.
Ⅳ、Installation
1、Choose a good position to instal the smoke alarm(ceiling)
2、Use the screw to fix the installation panel onto the ceiling.
3、Turn the smoke detector clockwise in order to fasten it to the installation panel tightly.
KD-135A/B/C/D/E Optical smoke alarm
15
1134
1134-CPR-101
EN 14604:2005/AC:2008
KD-135DoP001
The instruction of smoke alarm devices
Introduction
Design
KD-135A/B/C/D/E
Ⅰ. Technical parameter
Working Voltage:DC9V
Current:Quiescent Current:≤10uA
Alarming Current: ≤ 20mA
Alarming Decibel:≥85dB/3m
Low voltage Alarming:≤7.3V
Working Temperature: -10℃~+40℃
Working Humidity:≤95%RH
CAUTION!
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Test the alarm for correct operation using the test facility, whenever the battery is replaced.
Ⅲ、Test
Note:If the battery installed in wrong way, the detector will not work and maybe destroyed. If the detector operates smoothly, the Red LED will flash once in about 43S.
1、Contrarotate the installation panel in order to remove it;
2、Remove the insulated material and make sure the battery is connected in correct way;
3、Adjust the clips of the installation panel to the notches of the detector and turn the smoke detector clockwise in order to fasten it;
4、Depress the test button,the RED LED flashes quickly and in the mean while the detector sounds, it means the the detector works well.
Ⅳ、Installation
1、Choose a good position to instal the smoke alarm(ceiling)
2、Use the screw to fix the installation panel onto the ceiling.
3、Turn the smoke detector clockwise in order to fasten it to the installation panel tightly.