LM-101L fire detecting wireless online alarm is a kind of smoke alarm with photoelectric smoke detection and wireless online alarm function,When one of the alarms detects smoke signal, it could send out wireless alarm signal, trigger other alarms alarm(see effective transmission distance) , remind you that there are dangerous cases (fires) happening in time..
Availability:
Quantity:
sharethis sharing button
  • LM-101LD

  • OEM

  • 8531100000

LM-101L Fire Detecting Wireless Online Alarm Instruction


1、Brief introduction

LM-101L fire detecting wireless online alarm is a kind of smoke alarm with photoelectric smoke detection and wireless online alarm function,When one of the alarms detects smoke signal, it could send out wireless alarm signal, trigger other alarms alarm(see effective transmission distance) , remind you that there are dangerous cases (fires) happening in time..


2、Characteristic

◆ photoelectric smoke detection;

◆ High sensitivity;

◆ low power consumption;

◆ No. Of online set free


3、Technical parameters

(1)executive standard: BS EN 14604-2005

(2)working voltage: DC9V(for smoke detector)

        DC4.5V(for wireless online:1.5VX3pcs)

(3)working current:: DC9V quiescent current≤12uA

        DC9V alarm current≤ 20mA

        DC4.5V quiescent current≤230uA

        DC4.5V working current≤4mA

(4)alarm decibel:   ≥85dB/3m

(5)alarm indicator: red LED

(6)online/learn indicator:   red/green LED

(7)frequency:       433.92MHz

(8)transmission distance: spacious straight-line distance≤60m

(9)working temperature: -10℃~+40℃

(10)ambient humidity: ≤95%RH(no condensation)

(11)low battery test:DC9V(for smoke detector)<7.35V

                                       A brief alarm sound in about every 43 seconds

                                       DC4.5V(for wireless online)<3.3V

                                       A brief alarm sound in about every 60 seconds


4、Appearance and dimension(figure 1)

 

                                                                         figure 1


5、use

(1)Function diagram of cover base  mounting plate(figure 2)

企业微信截图_16129399666794  企业微信截图_16129400521698

                                                                                                      figure 2



(2)Battery mount(figure3)

a、Take out the product from packing box, rotate mounting plate anticlockwise, take out the 9 V and 1.5 V       battery,remove the protective film on the battery respectively.


b、put 9 v battery into the battery compartment and pay attention to The battery polarity symbol in compartment;

c、Please turn bayonet lock rocker to inwall before put 1.5V battery into compartment and pay attention to The battery polarity symbol in compartment;

d、aim  raised two hooks on mounting plate to two card slot on base .rotate mounting plate clockwise till hooks enter into card slot totally.

   figure3


(3)Test/Online/Delete memory

 Products entered the normal working state after power on and alarm indicator (red LED) flashes about  every 43s.

 test…

Press the test button ,alarm send out clear loud alarm signal tone,alarm indicator(red LED) is quickly flashing, online/learn indicator (red/green LED)is flashing and send out wireless alarm signal(online products in effective distance)at the same time. It shows that the alarm is in normal working state. We can also adopt artificial blowing smoke rest..

 Set/Online…

Host setting…Take any one of product(online need two or more products),press learn button once,,indicator light(red/green LED)changed once,set host to green indicator state ;

Slave setting…Set other products to red light state.

Online…

1、When the setting is correct,,Press the test button on host and hold it till the alarm indicator (red LED) and online/ learn indicator (red/green LED) flashing continuously, alarm send out wireless alarm signal to around at the same time ;

2、After the slave receive the online signal from host ,learn indicator will flash continuously .the alarms begin

to alarm at the same time and alarm lamp(red LED) is out.

3、After online setting ,take out one of alarms to press its test button ,the rest products will send out alarm and  flash continuously.

 Delete memory…Take one product do not need online. Press it’s learn button to set green state. Press test button to normal alarm state, then alarm indicator (red LED) and online/ learn indicator (red/green LED) flashing continuously, it is means the products had delete current online memory.


6、Installation sketch map (figure4)

(1)Choose a suitable installation position and effective communication distance;

(2)According to the holes of the installation board, drill a hole in the needed place of ceiling and stuff the plastic nail seat into the hole;

(3)Use the screw to fix the installation panel onto plastic nail seat;  

(4)Embed the two detector base hook into the detector slot. Turn the smoke detector clockwise in order to fasten it to the installation panel tightly.

(5)After installation, carry out the actual communication test to prevent the communication fault.

Figure 4


7、Maintenance

(1)It is better to test the smoke alarm weekly.

(2)Clean the alarm every three months. When cleaning, take out the battery. After finishing cleaning, press the test key to check the online condition.

(3)If you find the products are not in normal working state, check the battery first. If the problem can not be removed, please do not dismantle by yourself. You shall seek the service of the professional.


8、Failure analysis and elimination

failure phenomenon

analysis of causes

elimination method

remark

no response of the TEST key

9 V batteries are not installed correctly

Pay attention to the polarity and correctly install 9 V batteries.


no response of the LEARN key

4.5V batteries are not installed correctly

Pay attention to the polarity and correctly install 4.5 V batteries.


Make transient alarm sounds about every 43 seconds.

9 V batteries’voltage is low

Change 9 V battery


Make transient alarm sounds about every 60 seconds.

4.5V batteries’voltage is low

Change 4.5V battery



9、Points for Attention

(1)Do not install the product in the following environment such as hyper thermal, humid, dusty, kitchen, bathroom and so on;

(2)When installing, pay attention that there shall not be objects which will shelter from flash and block making sounds in front of the alarm.

(3)Install several online products to prevent them exceeding effective communication distance or objects which will block communication.


10、Points for Abandoned Products

(1)The packages are made up of renewable matters and please use them as circularly as possible;

(2)The batteries and waste electrical appliances that have been used can not be abandoned with normal household garbage.


11、Recommended Replacement Batteries

  Pair Deer  9V 6F22

  GP            9V 1604S

  Mustang  9V 6F22

  Pair Deer  9V 6LR61

  GP            9V 1604A

  Pair Deer  3 x 1.5V LR6/AA

  GP            3 x 1.5V GP15AU  

  Mustang   3 x 1.5V LR6/AA




Previous: 
Next: 

Related Articles

content is empty!

Related Products

Please Enter Your Information

Subscribe

Our main products include different kinds of smoke alarms, carbon monoxide alarms, gas alarms,water alarms,intelligent wireless alarm system , and other home electronics.

 

Contact us

    0574 62566055/62566056

    +86 13245660006

       +86 13081966918

   13245660006

       13081966918

  crystalwu@kingdun.com 

      maky-ding@kingdun.com

Menu

Menu

Copyright © 2021 Ningbo Kingdun Electronic Industry Co.,Ltd.  

Support by Leadong.com