KD-125C Smoke Alarm User Manual
2831-CPR-F2211
EN14604
1. Brief introduction
KD-125C Smoke Alarm is a photoelectric smoke alarm with low power consumption. Internal precise analog circuit and digital circuit make the detection work more stable and reliable. The product has a small size and uses large-capacity battery which can provide service life of 5 years.
2. Product characteristics
Photoelectric smoke detection
High sensitivity
Precise analog circuit and digital circuit
Low power consumption
Small size
Battery service life of 5 years
3. Technical parameters
4. Appearance and dimensions(Figure 1)
5. Installation
5.1 Functional diagram (Figure 2)
5.2 Installation Instructions
a. Hold the mounting plate against the selected installation position on the ceiling, and mark the center of the holes with a pencil. Drill a hole through the pencil marks and use the enclosed screws and anchors to secure the mounting plate. (See Figure 3)
b. Install the batteries according to Figure 3, making sure the polarity matches the markings. If the batteries are installed correctly, the red pin will drop automatically.
c. Insert the hook of the product into the slot of mounting plate. Then turn the alarm clockwise until it snaps into place.
Note: If you can’t rotate the alarm after insert the hook into the slot, please check if the battery is installed correctly.
5.3 Replacing battery
a. When low battery warning is made (please refer to section 6. Function), please replace the batteries immediately, as shown below.
Turn the alarm anticlockwise and Take the batteries out and install
remove it from the mounting plate. the new ones according to 5.2 b.
b. Use battery type: LR03/AAA.
c. Whenever the batteries are replaced, test the operation of the alarm by pressing the TEST button. If beeps are made which means the product works properly, install the alarm to the mounting plate as shown in Figure 3.
5.4 Recommended Locations for Smoke Alarms and Locations to Avoid
a. Recommended Locations for Smoke Alarms
Install at least one smoke alarm in every bedroom
If you install the smoke alarm in a passageway whose width is less than 3m, install it in the middle and install one unit every 12m.
At least 1.5m from fluorescent lamp or neon lamp. (In case of electronic interference).
At least 3m from the bathroom.
At least 6m from the kitchen or stove.
At least 30cm from the lamps.
Locate the smoke alarm in the middle of the room. If you can’t, install it at least 1m from the wall.
If you install the smoke alarm on sloped or peaked ceiling, the installation position shall be at least 90cm from the highest point.
b. Locations to Avoid
In the garage. Products of combustion are present when you start your automobile.
Near fresh air vents, fans, air conditioner or other drafty areas.
In an area where insects often appears.
In an area where the temperature may fall below 0℃ or rise above 40℃.
In humid areas. Bathroom. Kitchen.
content is empty!
Please Enter Your Information
Our main products include different kinds of smoke alarms, carbon monoxide alarms, gas alarms,water alarms,intelligent wireless alarm system , and other home electronics.
0574 62566055/62566056
+86 13245660006
+86 13081966918
13245660006
13081966918
Copyright © 2021 Ningbo Kingdun Electronic Industry Co.,Ltd.
Support by Leadong.com